CANADA BRICK DIVISION, JANNOCK BRICK LIMITED

TECHNICAL SERVICES LAB

TEST:
TEST NO.:
REFERENCE:
PLANT:
PANEL:
DISTRIBUTION:
DATE IN:
DATE OUT:
FREEZE THAW
MDFT8904
MASONRY DECOR STAIN APPLICATION
STREETSVILLE
RED WIRE MODULAR
J.J. PITT, J.P. STORER-FOLT, FILE
89.02.07
89.05.05
PROCEDURE:
Whole brick samples with a different stain concentration on half of each of the five bricks tested were supplied by Masonry Decor. These samples were subjected to a Freeze Thaw test in accordance with procedures outlined in C.S.A./CAN A82.1-M87 standards .
RESULTS:

SAMPLE NO. % STAIN STRENGTH % WEIGHT LOSS NO. OF CYCLES COMPLETED (P)ASS OR (F)AIL COATING DEGRADATION
1
2
3
4
5
100
75
50
25
5
0.03
0.02
0.04
0.01
0.03
50
50
50
50
50
P
P
P
P
P
LESS THAN 1%
APPROXIMATELY 1%
NOT DETECTED
NOT DETECTED
NOT DETECTED
AVERAGE % WEIGHT LOSS 0.03
STANDARD DEVIATION 0.01

COMMENTS:

  1. Since maximum allowable weight loss is 0.5%, all brick exceed CSA/CAN A82. 1-M87 and ASTM C216-86 freeze thaw requirements.
  2. Approximately 1% of coating degraded for sample stained at 75% strength, the remaining samples showed no visible signs of coating degradation over the 50 freeze thaw test period.

J.N. Storer-Folt, Technical Services Lab Supervisor